7 CONTROLS AND FUNCTIONS
Volume Control
This is only accessible when the front cover has been removed and will only affect
the volume of any extension speakers. The volume control is overridden when the
panel is in an alarm state, and also if the the panel has been set by either the Master
User or Limited User four digit codes. This feature will allow a reduced volume tone on
part-set modes.
Chime
Chime function applies to day mode only and if selected will cause the panel to
generate a three-note sound when an entry/exit zone is triggered. This feature is to
inform the occupants of the building that some one has entered.
Event Log
The Paragon Super control panel incorporates a memory log of the last 18 alarm
events and is accessible to both Users and the Engineer. It will record Fire, Intruder,
Personal Attack and Tamper alarms and also show if any of the 6 alarm zones have
been triggered or omitted.The Engineer can set the clearing of the log for either
Engineer-only or Master User and Engineer.
Auto Rearm
After an alarm the panel will automatically reset itself when the bell timer has expired.
Any zones which still remain triggered at that time will be omitted automatically.
Walk test
The walk test function allows each of the fullset / partset modes to be checked in
order to verify that all the intruder detectors on the alarm system are functioning
correctly. When undergoing a walk test the Engineer or Master User can choose
which of the set-modes he wishes to test. Any zones used in that set-mode will
cause a chime at the RKP or extension speaker l if they are triggered.
8 INSTALLATION AND WIRING
Before beginning any installation work read through this section carefully. Plan out the
various areas and degrees of protection required from each zone. It is important to
decide which type each zone should be if partsets are to be used. Work out the cable
routes avoiding mains cabling and consider the chosen position for the control panel
and its mains supply.
1 2 TECHNICAL SPECIFICATION
12.1 POWER SUPPLY/RKP
Power input
230V version : 230V ac +/- 10%, 50Hz/60Hz
220V version : 220V ac +/- 10%, 50Hz/60Hz
110V version : 110V ac +/- 10%, 50Hz/60Hz
Power input fuse
240, 230, 220V versions : 250 mA quick blow.
110V version : 500 mA quick blow.
Low voltage output : 13.2 Vdc fused, 0.5A Continuos 1.0A peak(20min)
Low voltage output fuse : 1 Amp quick blow.
Battery charge voltage : 13.7 Vdc
Rechargeable battery capacity : 12V sealed lead acid, 1.2 to 6 AH.
12.2 CONTROL PCB
Current consumption (day mode) : 45mA (quiescent)
: 55mA (with keypad LEDs)
(set mode) : 45mA
(test) : 120mA (all LEDs on)
(alarm ) : 210mA
Auxiliary DC output supply : Regulated 13.2 Vdc for use with PIR, microwave,
and shock sensors.
Extension Speaker load : 8 to 32 Ohms
Alarm Bell current : 0.5 Amps (maximum)
Alarm Bell timer : 2 to 20 minutes (software programmable)
Strobe current : 0.5 Amps (maximum)
Zone type : Normally closed loops which activate when opened or
connected to 0 volts from dc power supply.
Zone loop current : 1.2 to 1.5mA
Zone activation resistance : 2k Ohms (minimum)
Zone loop activation time : 0.35 seconds
Entry / Exit timer : 2 to 255 seconds (software programmable)
12.3 MECHANICAL
Dimensions : 223 x 205 x 78 mm (8.78 x 8.07 x 3.07 inches)
Case Material : 3mm thick Polycarbonate with screw fixing front cover
Colour : White
Weight (excluding battery) : 1.48 kg
12.4 ENVIRONMENTAL
Operating temperature : 0 to +40 deg C (+32to +104 deg F)
Storage temperature : -20 to +60 deg C (-4 to +140 deg F)
12.5 CLEANING
DO NOT use strong detergents to clean this panel. To remove any dirt or grime, wipe with a clean damp cloth ONLY.